reservoir characterization fractional flow

Chemical Tracers, Incorporated




in situ reservoir characterization

FRACTIONAL FLOW


SWCT. Non-destructive, in situ method for measuring fractional flow and relative permeability.

Deep investigation. Results typically represent hundreds of barrels of pore space in the test zone.

Native State. The tracers operate in native-state wetability pore space contacting live crude oil, live water at reservoir temperature. The problems that make laboratory measurement of these parameters difficult are easily overcome by carrying out the measurement in situ.

fractional flow

OPERATIONAL STEPS

1. Inject water plus 3 ester tracers into 100% oil production zone. Each tracer has a different partition coefficient (K value) as shown.
2. Push esters farther into zone with more water carrying a material balance tracer.
3. Shut in well for a two to six day period for hydrolysis reaction to proceed.
4. Produce well and analyze returning water for tracer content.
5. Calculate fractional flow from separation between reaction product alcohol tracers and remaining ester tracers.

MORE INFORMATION

Slide Show » View | Download PPT
Technical Bulletin » Download PDF
Brochure » Download PDF


oilfield service fractional flow

reservoir fractional flow informationView Slides

STEPS 1 AND 2

INJECTED ESTERS

K ~ 10

K ~ 5

K ~ 2

So1

So2

So3

OIL

Swc

STEP 3

Ester Tracers Partially Convert
to Alcohol via Hydrolysis Reaction

OIL

Swc

STEP 4

Alcohol and Remaining Ester Tracers
Separate During Production

OIL

Swc

oilfield service company